What the CS320 “Standard Enclosure” is
The CS320 Standard Enclosure is: A complete industrial door control panel housed in a full-size IP-rated cabinet
It combines:
- Microprocessor control electronics
- Power components (transformer, relays, protection)
- Operator interface (buttons / LCD)
- Wiring terminals
It’s the main “position box / control panel” used across Marantec industrial systems (MDF, DF/WF, Dynamic, etc.).
Enclosure (Housing) Specifications
Physical Construction
- Wall-mounted industrial control cabinet
- Integrated:
- Main switch
- Buttons (OPEN / STOP / CLOSE)
- Status LEDs / optional LCD
- Pre-mounted internal PCB and wiring
Dimensions
- Approx: 215 × 275 × 190 mm
Protection Rating
- IP65 (dust-tight, water-resistant)
Environmental
- Operating temperature: -20°C to +60°C
This makes it suitable for:
- Industrial environments
- Outdoor (protected) mounting
- Harsh warehouse conditions
Core Function (Control + Position Logic)
The CS320 enclosure contains the entire control system, responsible for:
Door Control
- Open / Close / Stop logic
- Motor direction control
- Brake handling
Position Handling
Supports:
- MEC (mechanical limit switches)
- AWG / digital encoder systems
One of its defining features is compatibility with both mechanical and electronic positioning systems.
Control System Features
Inputs / Outputs
- 4 programmable relay outputs (≈44 functions)
- 2 programmable inputs (≈27 functions)
- Additional programmable relay (extended logic)
Logic & Diagnostics
- Integrated error memory / fault log
- Cycle counter
- Status monitoring
- Diagnostics via LCD (optional)
The system records fault frequency and last occurrence cycles, aiding maintenance.
Electrical Specifications
Power Supply
- 400V 3-phase
- 230V 3-phase
- 230V single-phase
- Frequency: 50/60 Hz
Control Voltage
Output Capacity
- Max motor load:
- 2.2 kW (400V)
- 1.5 kW (230V 3~)
- 1.1 kW (230V 1~)
Auxiliary Supply
- 24V DC / 500 mA
- 230V AC / 1 A (for external devices)
Connectivity & Interfaces
Safety Systems
- Safety edges (8k2 / optical / OSE)
- Light barriers (multiple types)
- Emergency stop circuits
- Safety brake monitoring
Control Inputs
- Push buttons / key switches
- Remote radio modules (plug-in)
- Loop detectors
- Traffic light control
Supports two photoelectric barriers with multiple signal types (relay, NPN, PNP).
Expansion & Communication
- MS-Bus interface (for expansion modules)
- Plug-in modules:
- Radio receivers
- Timers
- I/O expansion
Programming & User Interface
Interface
- Built-in buttons (on enclosure)
- Optional LCD programmer
Programming Features
- Plain-text menu navigation
- Multi-language support
- Adjustable:
- Limits (if electronic)
- Timers
- Safety logic
- Relay functions
Programming uses a 3-button navigation system with LCD display.
Safety & Compliance
- Certified to EN 12453 (industrial door safety standard)
- Automatic safety device detection at startup
- Integrated safety inputs and monitoring
Operational Modes
- Dead-man operation
- Automatic (self-hold) operation
- Timed closing
- Traffic control logic (entry/exit systems)
System Integration
Compatible With:
- MDF series operators
- Dynamic series (e.g., Dynamic 400 MEC)
- DF / WF compact operators
Use Cases:
- Roller shutters
- Sectional doors
- High-speed doors
- Industrial gates
Designed for new installs AND retrofits of existing systems.
Standard Enclosure vs Mini Housing
| Feature |
CS320 Standard Enclosure |
Mini Housing |
| Role |
Main control panel |
Expansion / interface |
| Size |
Full cabinet |
Compact |
| Power handling |
Yes (motor control) |
No |
| UI (buttons/LCD) |
Yes |
No |
| Installation |
Central control point |
Distributed nodes |
(The Company reserves the right to amend product specifications and information without notice.)